Hydrogen Sulfide Gas (H²S)

Hydrogen sulfide (also known as H²S, sewer gas, swamp gas, stink damp, and sour damp) is a colorless gas known for its pungent "rotten egg" odor at low concentrations. It is extremely flammable and highly toxic. Oil and gas production across the western United States has increased dramatically and can have an impact on fire suppression operations and expose fire personnel to health hazards. Naturally occurring coal seams can produce potentially toxic gases as well.
Hydrogen sulfide is used or produced in a number of industries, such as:

  • Oil and gas refining
  • Mining
  • Tanning
  • Pulp and paper processing
  • Rayon manufacturing

Hydrogen sulfide also occurs naturally in sewers, manure pits, well water, oil and gas wells, and volcanoes.
At higher concentrations, H²S can result in respiratory paralysis, asphyxia, seizures, and death. Characteristics of a significant exposure are rapid knock down, respiratory depression, tremors, blurred vision, cyanosis, seizures, and elevated heart rate. H²S vapor can also travel considerable distances to a source of ignition and flash back explosively, giving off corrosive, and poisonous oxides of sulfur upon combustion.

To avoid exposure to H²S, here are some DO’s and DON’Ts concerning fire operations near oil and gas operations:

Do's:

  • If you are responding to a known oil and gas pad or coal seam areas, DO contact local petroleum engineer or resource advisor.
  • If your unit has known oil and gas operations or coal seams, DO ensure that every firefighter is provided with training on H²S.
  • If you happen upon a remote oil and gas pad area, DO cordon off the area with flagging, deny entry, and modify suppression tactics to avoid the area.
  • DO avoid low-lying drainages, ravines, and gullies near oil and gas pads and coal seams as they tend to accumulate higher air concentrations of potentially toxic gases, especially during early morning hours when air has the tendency to sink.
  • If you suspect that someone has been exposed to H²S, DO seek medical care immediately at the nearest hospital.

Don'ts:

  • DON’T locate fire camps, Incident Command Posts (ICP), or helispots on, or near oil and gas pads.
  • DON’T depend on sense of smell for warning – H²S causes rapid deterioration of sense of smell.
  • DON’T attempt fire suppression on or near oil and gas pads. Local petroleum engineers or resource advisors may recommend safe working distances, and firefighters may also be given H²S monitors when working near oil and gas pad operations and/or coal seams.
  • DON’T wait to seek medical attention if H²S exposure is suspected.

 

Last Modified / Reviewed:

Have an idea or feedback?

Share it with the NWCG 6MFS Subcommittee.


Follow NWCG on Twitter and Facebook

NWCG Latest Announcements

NWCG Equipment Technology Committee Releases Safety Warning: 25-001 Non-specification fire shelters

Date: January 15, 2025
Contact: Equipment Technology Committee

The Equipment Technology Committee (ETC) has released Safety Warning: 25-001 Non-specification fire shelters. Non-specification fire shelters claiming to meet Forest Service (FS) fire shelter specification 5100-606 were first found in February of 2023. As of September 2024, non-specification shelters are again being advertised and sold on the open market.

This Safety Warning outlines details and recommended procedures to purchase FS specification shelters made with materials and components that meet performance criteria and toxicity testing requirements outlined in FS Specification 5100-606. 

For additional information on identifying non-specification shelters, please view ETC Safety Warning 23-01.

References:

ETC Safety Warning 25-001: Non-specification fire shelters

NWCG Equipment Technology Committee

ETC Safety Warning 23-01

Paul Gleason Lead by Example Awards

Date: January 14, 2025
Contact: Leadership Committee

The NWCG Leadership Committee has awarded the 2023 Paul Gleason “Lead By Example” awards to individuals in the categories of Initiative and Innovation, Mentoring and Teamwork, and Motivation and Vision, as well as a Lifetime Achievement Award.

Congratulations to the awardees:

  • Sam Bowen, Superintendent of the Mark Twain Veteran Crew with the U.S. Forest Service.
  • Greg Titus, Zone Fire Management Officer for the St. Marks National Wildlife Refuge with U.S. Fish and Wildlife Service.
  • Renae Crippen, Manager of the Blue Mountain Interagency Dispatch Center with the U.S. Forest Service.
  • Eric Carlson, Instructor with OMNA International.

References:

Paul Gleason Lead by Example Award

Wildland Fire Leadership Development Program

Interview with Paul Gleason

Updated NWCG Standards for Water Scooping Operations, PMS 518

Date: December 19, 2024
Contact: Water Scooper Operations Unit

The NWCG Standards for Water Scooping Operations, PMS 518 establishes the standards for dispatching, utilizing, and coordinating water scooping aircraft on interagency wildland fires. These standards should be used in conjunction with the NWCG Standards for Aerial Supervision (SAS), PMS 505, and any local, state, or geographic/regional water scooping plans.

References:

NWCG Standards for Water Scooping Operations, PMS 518

Updated NWCG Standards for Aerial Supervision, PMS 505

Date: December 19, 2024
Contact: Interagency Aerial Supervision Subcommittee

The Interagency Aerial Supervision Subcommittee has updated the NWCG Standards for Aerial Supervision, PMS 505. PMS 505 establishes standards for aerial supervision operations for national interagency wildland fire operations. 

References:

NWCG Standards for Aerial Supervision, PMS 505