Avoiding Fuel Geysering

triangle with image of spraying fumes at person with the words fuel, heat, and pressure on each side of triangle.

 

Fuel geysers continue to be reported and the potential for injury is real. In 2018, there were 28 incidents of fuel geyser reported: 23 chainsaws, a leaf blower, and four jerry cans. A fuel geyser can happen on any equipment with a fuel tank including fuel bottles and containers. Even chainsaws with two-way vents may “geyser” at high temperatures or high elevation. Users should assume all gas-powered equipment and fuel containers are pressurized.

Fuel – Know Your Fuel

  • Fuel volatility changes seasonally and geographically.
  • Think locally. Using fuel from a cooler climate (i.e., Idaho) in a warmer climate (i.e., Texas) increases the geysering potential.
  • As elevation increases, boiling point temperatures decrease. 125oF at 8,000 feet is approximately equivalent to 140oF at 1,000 feet.

Fuel Bottles and Containers

Fuel bottles (i.e., Sigg bottles), fuel containers (i.e., dolmars or jerry cans) can geyser even after the cap is removed. To mitigate possible fuel geyser and/or potential injury from fuel bottles and cans, use the following procedures:

  • Keep containers in the shade and away from any external heat source.
  • Never open a fuel tank within 20 feet of any heat source.
  • Gently shake the container to release surface tension. Too much agitation will create pressure.
  • Open container slowly, pointing opening away and cover the opening with a cloth and glove.

Engine Powered Equipment

  • Never use fuel that was stored in a fuel container for longer than one month. Older fuel may lead to poor engine performance and increased operating temperatures. Older fuel may also have higher volatility for the current conditions. 
  • Always check the fuel level in the tank before taking any action. Fuel levels above ½ tank are more likely to geyser.
  • Never open a fuel tank within 20 feet of any heat source.
  • Only after the above mitigations are completed; put the equipment in a cleared area, cover the cap with a cloth or glove, and open slowly.

For more information or if you experience a fuel geyser, see the Fuel Geyser Awareness section at 
https://www.nwcg.gov/committees/equipment-technology-committee

 

Last Modified / Reviewed:


Have an idea or feedback?

Share it with the NWCG 6MFS Subcommittee
 


Follow NWCG on X and Facebook
 


 

NWCG Latest Announcements

NWCG Standards for Wildland Fire Chainsaw Operations, PMS 212, and Next Generation Position Task Book for Basic Faller Are Now Available

Date: April 14, 2025
Questions?  Please contact:
Hazard Tree and Tree Felling Subcommittee

The updated NWCG Standards for Wildland Fire Chainsaw Operations, PMS 212, and NWCG Position Task Book for Basic Faller (FAL3), PMS 311-19 are now available.

The NWCG Standards for Wildland Fire Chainsaw Operations, PMS 212 includes position standards designed to be used in conjunction with the Next Generation Position Task Book (Next Gen PTB). The Next Gen PTB for Basic Faller (FAL3) includes an evaluation guide with suggested rating elements to consider when assessing trainees.

References:

NWCG Standards For Wildland Fire Chainsaw Operations, PMS 212

NWCG Position Task Book for Basic Faller (FAL3), PMS 311-119

NWCG Basic Faller (FAL3)

RMC Memo 25-01: Summary of Updates to Safety Officer Positions

Date: April 9, 2025
Questions?  Please contact:
RMC Member Eric Fransted

The Risk Management Committee (RMC) serves as the position steward for all Safety Officer incident positions and continues to improve position standards, training, and naming conventions. The implementation of Complex Incident Management (CIM) required changes to position titles. RMC collaborated with the NWCG Incident Position Standards Committee (IPSC) to propose and implement these updates. 

References:

RMC Memo 25-01: Summary of Updates to Safety Officer Positions 

NWCG Position Catalog

Updated, NWCG Guide to Wildland Fire Origin and Cause Determination, PMS 412

Date: April 8, 2025
Questions?  Please contact:
Wildland Fire Investigation Subcommittee

PMS 412 provides guidance for wildland fire investigations. This guide outlines recommended procedures, practices, techniques, and methods to promote a systematic approach. The last update to this publication was in 2016.

References:

NWCG Guide to Wildland Fire Origin and Cause Determination PMS 412

Updated NWCG Standards for Airtanker Base Operations, PMS 508

Date: March 31, 2025
Questions?  Please contact:
Airtanker Base Operations Unit

The updated NWCG Standards for Airtanker Base Operations (SABO), PMS 508 standardizes operations and procedures at interagency airtanker bases to ensure safe, efficient, and effective operations in support of interagency goals and objectives.

References:

NWCG Standards for Airtanker Base Operations, PMS 508