Skip to main content

Safety Zone Research

 

Please watch the video for this subject.

Time 6:15

 

First, a Fire Behavior 101 refresher:  You can warm yourself around the sides of a campfire for quite some time; that’s radiant heat. If you hold your hands over the top of the fire, you’ll get burned relatively quickly; that’s convective heat.

Basically, wind or slope can tip the flames over, so that the convective heat is no longer going straight up, but is now aimed more along the ground, sending the heat and hot gasses much further ahead. This causes preheating of the fuels, faster fire spread, and greater fire intensities. You’ll need a larger safety zone if that fire is coming towards you.

The current equation for safety zone size on the Safety Zones page of the Incident Response Pocket Guide (IRPG), PMS 461:

4 x Flame Height = Safe Separation Distance

To make estimations of flame height though, you either have to use past fire behavior observations or use your experience to guess what the fire may do in the future. After a decade of research, Bret Butler, at the Missoula Technology and Development Center, suggests removing the uncertainty and guesswork that comes with estimating flame height by taking the general rule of thumb:

Flame Height = 2 x Vegetation Height

…and substituting that Flame Height equation into the original IRPG equation, to give:

4 x 2 x Vegetation Height = Safe Separation Distance, which simplified is:
 8 x Vegetation Height = Safe Separation Distance

But remember, that’s still for radiant heat only, on flat ground, with no wind. To take into account the convective heat from slope or wind, Butler’s research suggests that a Slope Wind Factor is needed in the equation:

8 x Vegetation Height x Slope Wind Factor = Safe Separation Distance

But what is the Slope Wind Factor? Current research is indicating that the Slope Wind Factor is between 1 and 10, with Butler arguing it may be closer to between 1 and 5. Butler’s ongoing research is focused on answering that question by gathering sensor data on fires, running computer simulations, and refining the models.

In the meantime, utilize the calculations in the Safety Zones page of your IRPG to help you determine a bare minimum size for your safety zone with the understanding that slope and wind need to be considered in your decision-making.

But remember, a safety zone is only good if you can get there.

 

Last Modified / Reviewed:


Have an idea or feedback?

Share it with the NWCG 6MFS Subcommittee
 


Follow NWCG on X and Facebook
 


 

NWCG Latest Announcements

NWCG Standards for Wildland Fire Chainsaw Operations, PMS 212, and Next Generation Position Task Book for Basic Faller Are Now Available

Date: April 14, 2025
Questions?  Please contact:
Hazard Tree and Tree Felling Subcommittee

The updated NWCG Standards for Wildland Fire Chainsaw Operations, PMS 212, and NWCG Position Task Book for Basic Faller (FAL3), PMS 311-19 are now available.

The NWCG Standards for Wildland Fire Chainsaw Operations, PMS 212 includes position standards designed to be used in conjunction with the Next Generation Position Task Book (Next Gen PTB). The Next Gen PTB for Basic Faller (FAL3) includes an evaluation guide with suggested rating elements to consider when assessing trainees.

References:

NWCG Standards For Wildland Fire Chainsaw Operations, PMS 212

NWCG Position Task Book for Basic Faller (FAL3), PMS 311-119

NWCG Basic Faller (FAL3)

RMC Memo 25-01: Summary of Updates to Safety Officer Positions

Date: April 9, 2025
Questions?  Please contact:
RMC Member Eric Fransted

The Risk Management Committee (RMC) serves as the position steward for all Safety Officer incident positions and continues to improve position standards, training, and naming conventions. The implementation of Complex Incident Management (CIM) required changes to position titles. RMC collaborated with the NWCG Incident Position Standards Committee (IPSC) to propose and implement these updates. 

References:

RMC Memo 25-01: Summary of Updates to Safety Officer Positions 

NWCG Position Catalog

Updated, NWCG Guide to Wildland Fire Origin and Cause Determination, PMS 412

Date: April 8, 2025
Questions?  Please contact:
Wildland Fire Investigation Subcommittee

PMS 412 provides guidance for wildland fire investigations. This guide outlines recommended procedures, practices, techniques, and methods to promote a systematic approach. The last update to this publication was in 2016.

References:

NWCG Guide to Wildland Fire Origin and Cause Determination PMS 412

Updated NWCG Standards for Airtanker Base Operations, PMS 508

Date: March 31, 2025
Questions?  Please contact:
Airtanker Base Operations Unit

The updated NWCG Standards for Airtanker Base Operations (SABO), PMS 508 standardizes operations and procedures at interagency airtanker bases to ensure safe, efficient, and effective operations in support of interagency goals and objectives.

References:

NWCG Standards for Airtanker Base Operations, PMS 508