Skip to main content

Can – Gasoline, Safety, 5 GL, DOT Approved

NFES #
000606
Category
Fuel Handling
Updated
Storage and Shelf Life Checks
Yes
Storage and Shelf Life Procedure
If stored outside protect from rain, snow, or any form of moisture.

Initial inspection/Disposal Criteria

  1. Inspect for fuel or mixes and dispose of properly.
  2. Using a mirror and flashlight, inspect the ceiling of the can for additional rust. Inspect all interior surfaces for rust that has pitted, is flaking, or is lifting the interior surface.  Spots larger than a quarter, or collectively multiple areas larger than a quarter, will render the can unserviceable.  Some flash rust may be present and is acceptable. 
  3. Inspect for impacts or dents to corners and seams as separation and/or leaks may occur.
  4. Inspect all threads on nozzles for serviceability.
  5. If can is a quick coupler type, push nozzle into place ensuring that lock button clicks.
  6. Inspect spring closure devices to be sure they are functioning properly.
  7. Inspect for can integrity and uniformity, i.e., collar crushed, large dents, punctures, modifications.
  8. Inspect all cotter keys and pins.
  9. Ensure that containers are properly marked and labeled.
  10. Ensure spark arrester screen is present. Replace screen as necessary.
  11. Return to stock if item shows no signs of use and passes visual inspection.
  12. Refurbish if item has been used and/or damage is repairable.
  13. Dispose of item if damage is found and it cannot be repaired.

Refurbishing Procedures

A. Cleaning

  1. Drain all existing fuel.
  2. With pressure washer and detergent wash outside of container.
  3. Clean and dry the interior of the container utilizing evacuators, swabbing, and air drying.  Using a forced air process is not recommended as excess vapors can create a hazardous environment.
  4. Turn upside down with lids off or open to dry.
  5. Spray inside of can lightly with WD-40 or similar product.

B. Repair

  1. Replace rubber O-ring in discharge port of pin-lock style gas cans.
  2. Replace any defective cotter key or pins.
  3. Wipe down outside of container and repaint if necessary.
  4. Ensure container is properly marked and labeled. Color requirement for the can is red with yellow markings. Label shall be FLAMMABLE LIQUID as well as a 1-inch yellow vinyl strip around the bottom of the can (see photo below for example) Markings are dependent on fuel type and can be accomplished using NFES tags #000805, #000802, #000803, #000801. See the NWCG Standards for Transporting Fuel, PMS 442, for more information.
  5. Chain is not required but can be utilized if easily repaired.

C. Tests for Performance

  • None

D. Repackaging

  • Ensure spout is zip tied to handle.

Closeup of the top of a fuel can with the hose zip tied to the handle. Red gas can with spout.

 

 

NWCG Latest Announcements

NWCG Standards for Wildland Fire Chainsaw Operations, PMS 212, and Next Generation Position Task Book for Basic Faller Are Now Available

Date: April 14, 2025
Questions?  Please contact:
Hazard Tree and Tree Felling Subcommittee

The updated NWCG Standards for Wildland Fire Chainsaw Operations, PMS 212, and NWCG Position Task Book for Basic Faller (FAL3), PMS 311-19 are now available.

The NWCG Standards for Wildland Fire Chainsaw Operations, PMS 212 includes position standards designed to be used in conjunction with the Next Generation Position Task Book (Next Gen PTB). The Next Gen PTB for Basic Faller (FAL3) includes an evaluation guide with suggested rating elements to consider when assessing trainees.

References:

NWCG Standards For Wildland Fire Chainsaw Operations, PMS 212

NWCG Position Task Book for Basic Faller (FAL3), PMS 311-119

NWCG Basic Faller (FAL3)

RMC Memo 25-01: Summary of Updates to Safety Officer Positions

Date: April 9, 2025
Questions?  Please contact:
RMC Member Eric Fransted

The Risk Management Committee (RMC) serves as the position steward for all Safety Officer incident positions and continues to improve position standards, training, and naming conventions. The implementation of Complex Incident Management (CIM) required changes to position titles. RMC collaborated with the NWCG Incident Position Standards Committee (IPSC) to propose and implement these updates. 

References:

RMC Memo 25-01: Summary of Updates to Safety Officer Positions 

NWCG Position Catalog

Updated, NWCG Guide to Wildland Fire Origin and Cause Determination, PMS 412

Date: April 8, 2025
Questions?  Please contact:
Wildland Fire Investigation Subcommittee

PMS 412 provides guidance for wildland fire investigations. This guide outlines recommended procedures, practices, techniques, and methods to promote a systematic approach. The last update to this publication was in 2016.

References:

NWCG Guide to Wildland Fire Origin and Cause Determination PMS 412

Updated NWCG Standards for Airtanker Base Operations, PMS 508

Date: March 31, 2025
Questions?  Please contact:
Airtanker Base Operations Unit

The updated NWCG Standards for Airtanker Base Operations (SABO), PMS 508 standardizes operations and procedures at interagency airtanker bases to ensure safe, efficient, and effective operations in support of interagency goals and objectives.

References:

NWCG Standards for Airtanker Base Operations, PMS 508