Skip to main content

Can – Gasoline, Safety, 5 GL, DOT Approved, Alternative to 000606

NFES #
000607
Category
Fuel Handling
Updated
Storage and Shelf Life Checks
Yes
Storage and Shelf Life Procedure
If stored outside protect from rain, snow, or any form of moisture.

Palet of fuel cans in warehouse

Initial inspection/Disposal Criteria

  1. Inspect for fuel or mixes and dispose of properly.
  2. Using a mirror and flashlight, inspect the ceiling of the can for additional rust. Inspect all interior surfaces for rust that has pitted, is flaking, or is lifting the interior surface. Spots larger than a quarter or collectively multiple areas larger than a quarter will render the can unserviceable. Some “flash rust” maybe present and is acceptable.
  3. Inspect for galvanic corrosion (White Rust). May appear to look like powder.
  4. Inspect for impacts or dents to corners and seams as separation and/or leaks may occur.
  5. Inspect nozzle, gasket, and screws for serviceability.
  6. Inspect spring closure devices to be sure they are functioning properly.
  7. Inspect for can integrity and uniformity, i.e., collar crushed, large dents, punctures, modifications.
  8. Inspect all cotter keys and pins.
  9. Ensure that containers are properly marked and labeled.
  10. Ensure spark arrester screen is present. Replace screen as necessary.
  11. Return to stock if item shows no signs of use and passes visual inspection.
  12. Refurbish if item has been used and/or damage is repairable.
  13. Dispose of item if damage is found and it cannot be repaired.

Refurbishing Procedures

A. Cleaning

  1. Drain all existing fuel.
  2. With pressure washer and detergent, wash outside of container.
  3. Clean and dry the interior of the container utilizing evacuators, swabbing, and air drying. Using a forced air process is not recommended as excess vapors can create a hazardous environment.
  4. Turn upside down with lids off or open to dry.
  5. Spray inside of can lightly with WD-40 or similar product.

B. Repair

  1. Replace gasket and screws if needed.
  2. Replace any defective cotter key or pins.
  3. Wipe down outside of container and repaint if necessary.
  4. Ensure container is properly marked and labeled. Color requirement for the can is red with yellow markings. Label shall be FLAMMABLE LIQUID. Markings are dependent on fuel type and can be accomplished using NFES tags #000805, #000802, #000803, #000801.
  5. Place nozzle, gasket, and screws in a sealed bag. Put in box with can.
     
    Links for ordering replacement parts.
    NFES DESCRIPTION LINK
    0617 HOLD-DOWN BRACKET FOR FILL CAP Hold Down Replacement Kit | DOT Safety Cans | 11010 | Justrite
      FLAME ARRESTOR FOR FILL CAP Stainless Steel Flame Arrester | For Type I & Type II Cans | 11007 | Justrite
      FLEXIBLE HOSE 1” OD - REPLACEMENT Flexible Hose Replacement for Type II Safety Cans | 1-Inch | 11077 | Justrite
      GASKET, FLEXIBLE HOSE Hose Gasket for Safety Cans | Type II, DOT | 11073 | Justrite

     

C. Tests for Performance

  • None

D. Repackaging

  • Attach spout and stack on a pallet. Twelve to a layer with flat cardboard in between each layer. Three high makes 36 per pallet. Ensure spouts are facing in.

Palet of fuel cans in warehouse palet of fuel cans stacked two high in warehouse

  • Secure handle to body container (example below)

Handle on can. Handle zip tied to can.

 

 

NWCG Latest Announcements

NWCG Standards for Wildland Fire Chainsaw Operations, PMS 212, and Next Generation Position Task Book for Basic Faller Are Now Available

Date: April 14, 2025
Questions?  Please contact:
Hazard Tree and Tree Felling Subcommittee

The updated NWCG Standards for Wildland Fire Chainsaw Operations, PMS 212, and NWCG Position Task Book for Basic Faller (FAL3), PMS 311-19 are now available.

The NWCG Standards for Wildland Fire Chainsaw Operations, PMS 212 includes position standards designed to be used in conjunction with the Next Generation Position Task Book (Next Gen PTB). The Next Gen PTB for Basic Faller (FAL3) includes an evaluation guide with suggested rating elements to consider when assessing trainees.

References:

NWCG Standards For Wildland Fire Chainsaw Operations, PMS 212

NWCG Position Task Book for Basic Faller (FAL3), PMS 311-119

NWCG Basic Faller (FAL3)

RMC Memo 25-01: Summary of Updates to Safety Officer Positions

Date: April 9, 2025
Questions?  Please contact:
RMC Member Eric Fransted

The Risk Management Committee (RMC) serves as the position steward for all Safety Officer incident positions and continues to improve position standards, training, and naming conventions. The implementation of Complex Incident Management (CIM) required changes to position titles. RMC collaborated with the NWCG Incident Position Standards Committee (IPSC) to propose and implement these updates. 

References:

RMC Memo 25-01: Summary of Updates to Safety Officer Positions 

NWCG Position Catalog

Updated, NWCG Guide to Wildland Fire Origin and Cause Determination, PMS 412

Date: April 8, 2025
Questions?  Please contact:
Wildland Fire Investigation Subcommittee

PMS 412 provides guidance for wildland fire investigations. This guide outlines recommended procedures, practices, techniques, and methods to promote a systematic approach. The last update to this publication was in 2016.

References:

NWCG Guide to Wildland Fire Origin and Cause Determination PMS 412

Updated NWCG Standards for Airtanker Base Operations, PMS 508

Date: March 31, 2025
Questions?  Please contact:
Airtanker Base Operations Unit

The updated NWCG Standards for Airtanker Base Operations (SABO), PMS 508 standardizes operations and procedures at interagency airtanker bases to ensure safe, efficient, and effective operations in support of interagency goals and objectives.

References:

NWCG Standards for Airtanker Base Operations, PMS 508