Skip to main content

Can – 5 GL (18.9L), Gas, Safety, Vented

NFES #
001291
Category
Fuel Handling
Updated
Storage and Shelf Life Checks
Yes
Storage and Shelf Life Procedure
If stored outside protect from rain, snow or any form of moisture.

Initial inspection/Disposal Criteria

  1. Inspect for fuel or mixes and dispose of properly.
  2. Inspect for rust that has pitted, is flaking or is lifting the interior surface and determine extent as some “flash rust” maybe present.
  3. Inspect for leaks or separation along seams.
  4. Inspect all threads on nozzles for serviceability.
  5. Inspect spring closure devices to be sure they are functioning properly.
  6. Inspect for can integrity and uniformity, i.e. collar crushed, large dents, punctures, modifications.
  7. Inspect all cotter keys and pins.
  8.  Ensure that containers are properly marked and labeled.
  9. Ensure spark arrester screen is present, replace as necessary.
  10. Return to stock if item shows no signs of use and passes visual inspection.
  11. Refurbish if item has been used and/or damage is repairable.
  12. Dispose of item if damage is found and it cannot be repaired.

Refurbishing Procedures

A. Cleaning

  1. Drain all existing fuel.
  2. With pressure washer and detergent wash outside of container.
  3. Use a rag and air hose or some means to dry the interior of the container.
  4. Turn upside down with lids off or open to dry.
  5. Spray inside of can lightly with WD-40 or similar product.

B. Repair

  1. Replace any defective cotter key or pins.
  2. Wipe down outside of container and repaint if necessary. 
  3. Ensure container is properly marked and labeled. Color requirement for the cans are red with yellow markings. Label shall be FLAMMABLE LIQUID. Markings are dependent on fuel type and can be accomplished using NFES tags #000805, #000802, #000803, #000801.
  4. Ensure fuel geyser warning label is present and legible near spout area. Reference cache memo 17-2 below.
  5. Secure proper spout to top of can, if applicable.

C. Tests for Performance

  • None

D. Repackaging

  • None

 

NWCG Latest Announcements

Updated NWCG Guide for Wildland Fire Modules, PMS 431

Date: May 14, 2025
Questions?  Please contact:
Fire Use Subcommittee

The updated NWCG Guide for Wildland Fire Modules, PMS 431 serves as a supplemental resource for wildland fire module operations, providing information frequently used in the field.

PMS 431 defines the organizational structure, staffing, and qualifications for Type 1 and Type 2 Wildland Fire Modules, outlining their roles in wildland fire suppression, prescribed fire, and resource management. The NWCG Guide for Wildland Fire Modules, PMS 431, should be used in conjunction with the NWCG Standards for Wildland Fire Module Operations, PMS 430.

References:

NWCG Guide for Wildland Fire Modules, PMS 431

NWCG Standards for Wildland Fire Module Operations, PMS 430

Updated NWCG Standards for Wildland Fire Resource Typing, PMS 200 Now Includes Off-Highway Vehicle Typing Standards

Date: May 13, 2025
Questions?  Please contact:
Mobile Fire Equipment Subcommittee 

The NWCG Standards for Wildland Fire Resource Typing, PMS 200 has been updated to include newly developed Off-Highway Vehicle (OHV) typing standards. These standards organize OHV information into logical categories and outline key safety requirements for occupants.

NWCG Standards for Wildland Fire Resource Typing, PMS 200 establishes minimum typing standards for aircraft, crews, and equipment used in national mobilization to wildland fire incidents. Typing designations are assigned based on measurable capability and performance criteria.

References:

NWCG Standards for Wildland Fire Resource Typing, PMS 200

NEW! S-204, Interpersonal and Critical Thinking Skills for Safety Officers Now Available

Date: May 12, 2025
Questions?  Please contact:
Risk Management Committee

The S-204, Interpersonal and Critical Thinking Skills for Safety Officers self-directed online course is now available! Developed through the Incident Performance and Training Modernization (IPTM) effort, this training supports individuals working towards Safety Officer, Field (SOFF) incident qualifications.

S-204, Interpersonal and Critical Thinking Skills for Safety Officers focuses on facilitating hazard mitigation conversations and building trust to influence safety-related decisions. Individuals can self-enroll through the Wildland Fire Learning Portal (WFLP).

Any changes to qualification pathways will take effect with the next update of the NWCG Standards for Wildland Fire Position Qualifications, PMS 310-1.

References:

S-204, Interpersonal and Critical Thinking Skills for Safety Officers 

NWCG Safety Officer, Field (SOFF) Position Page

Wildland Fire Learning Portal

Great Basin Cache Upgrading to New Inventory System

Date: May 7, 2025
Questions?  Please contact:
Great Basin Cache
Phone: (208) 387-5104
Fax: (208) 387-5573

The Great Basin Cache (GBK) is transitioning to a new inventory system to better serve the wildland fire community. During this upgrade, GBK will be unable to process standard orders from Part 1: Fire Supplies and Equipment and Part 2: Publications between May 8-20, 2025, with exceptions made for emergency fire orders. Orders will be accepted through close of business May 7.

To browse the latest available items, please refer to the National Fire Equipment System (NFES) catalogs. 

References:

NWCG NFES Catalog-Part 1: Fire Supplies and Equipment, PMS 449-1

NWCG NFES Catalog-Part 2: Publications, PMS 449-2