Skip to main content

Pump – Trombone, Backpack, Single Action

NFES #
000151
Category
Water Handling
Updated
Storage and Shelf Life Checks
None

Initial Inspection/Disposal Criteria

  1. Inspect for obvious damage. 
  2. Inspect for burns and cracks. Dispose of if these are found.
  3. Inspect for damaged threads. If beyond repair dispose of. Ensure tip is secured to wand with a 3-4 inch length of ball chain.
  4. Place hose in water and pump handle to validate that pump works properly.
  5. Return item to stock if it shows no sign of use or damage.
  6. Dispose of item if unable to repair.

Refurbishing Procedures

A. Cleaning

  1. Wash and clean all items of foreign matter, such as mud, dirt, and grease.
  2. Clean in mild detergent with brush or scouring pad as needed.
  3. Rinse thoroughly.

B. Repair

  1. If pump pressure is not sufficient, remove pump unit and replace O-rings.
  2. If suction hose is kinked, replace hose.
  3. Ensure quick connection on pump has proper seating.
  4. Check hose connection to pump for tightness; if loose, use a hose clamp.
  5. Replace length of ball chain between wand and removable tip if missing.
  6. Check supply hose on pump assembly for obstructions and tight connections, bent push rods, and clogged tips.
  7. Check spring and ball bearing.
  8. Lubricate slide with appropriate lubricant, e.g., Chevron NLGI2 or equivalent.

C.  Tests for Performance

  • Place end of hose in water and pump trombone. Ensure that it fills and discharges water properly without back feeding water out of the suction hose.

D.  Repackaging

  1. Suggested packaging of NFES #000151, 10 each in NFES #000385 carton (7.25” x 9.25” x 26”) or 25 each in NFES #002006 carton (23” x 19” x 10”).
  2. Ensure suction hose is not kinked when packaging.

 

NWCG Latest Announcements

NWCG Standards for Wildland Fire Chainsaw Operations, PMS 212, and Next Generation Position Task Book for Basic Faller Are Now Available

Date: April 14, 2025
Questions?  Please contact:
Hazard Tree and Tree Felling Subcommittee

The updated NWCG Standards for Wildland Fire Chainsaw Operations, PMS 212, and NWCG Position Task Book for Basic Faller (FAL3), PMS 311-19 are now available.

The NWCG Standards for Wildland Fire Chainsaw Operations, PMS 212 includes position standards designed to be used in conjunction with the Next Generation Position Task Book (Next Gen PTB). The Next Gen PTB for Basic Faller (FAL3) includes an evaluation guide with suggested rating elements to consider when assessing trainees.

References:

NWCG Standards For Wildland Fire Chainsaw Operations, PMS 212

NWCG Position Task Book for Basic Faller (FAL3), PMS 311-119

NWCG Basic Faller (FAL3)

RMC Memo 25-01: Summary of Updates to Safety Officer Positions

Date: April 9, 2025
Questions?  Please contact:
RMC Member Eric Fransted

The Risk Management Committee (RMC) serves as the position steward for all Safety Officer incident positions and continues to improve position standards, training, and naming conventions. The implementation of Complex Incident Management (CIM) required changes to position titles. RMC collaborated with the NWCG Incident Position Standards Committee (IPSC) to propose and implement these updates. 

References:

RMC Memo 25-01: Summary of Updates to Safety Officer Positions 

NWCG Position Catalog

Updated, NWCG Guide to Wildland Fire Origin and Cause Determination, PMS 412

Date: April 8, 2025
Questions?  Please contact:
Wildland Fire Investigation Subcommittee

PMS 412 provides guidance for wildland fire investigations. This guide outlines recommended procedures, practices, techniques, and methods to promote a systematic approach. The last update to this publication was in 2016.

References:

NWCG Guide to Wildland Fire Origin and Cause Determination PMS 412

Updated NWCG Standards for Airtanker Base Operations, PMS 508

Date: March 31, 2025
Questions?  Please contact:
Airtanker Base Operations Unit

The updated NWCG Standards for Airtanker Base Operations (SABO), PMS 508 standardizes operations and procedures at interagency airtanker bases to ensure safe, efficient, and effective operations in support of interagency goals and objectives.

References: