Skip to main content

Tee – Hoseline, w/Valve, 1 1/2” NH-F X 1 1/2” NH-M X 1” NPSH-M

NFES #
000230
Category
Water Handling
Updated
Storage and Shelf Life Checks
None

Initial Inspection/Disposal Criteria

  1. Inspect for burrs, gaskets, and fire damage. NFES # 000230 ONLY: Ensure that 1” valve waterway is 0.50 inches in diameter is seated properly with O-rings in place.
  2. Return to stock if item is clean, passes inspection and is in unused condition.
  3. Refurbish if damaged components are replaceable, if burrs can easily be filed down and if gaskets can be replaced.
  4. Dispose of item if it fails inspection, fails Testing for Performance, or has fire damage.

Refurbishing Procedures

A. Cleaning

  1. Powerwash with mild soap, using a stiff brush if necessary.
  2. Rinse thoroughly and stand upright to dry.

B. Repair

  1. Replace missing or cracked gaskets.
  2. File burrs from threads if practical.

C. Testing for Performance

  1. Check threads function by using appropriate female fitting. Additional Testing for Performance (NFES # 000230 ONLY).
  2. Install tee on pump.
  3. Open handle on valve.
  4. Turn on water.
  5. Close handle.
  6. Turn on pump to 300 PSI and hold for 3 minutes.
  7. Inspect for leaks:
    • Gasket
    • Under valve handle

D. Repackaging

  • Stand upright and dry completely prior to packaging.
    • Use NFES #008064 (10”x 8 x 6”) 10 per carton (see photos below for suggested packaging pattern).

0230-tee packaging for five units.

0230-tee packaging

 

NWCG Latest Announcements

NWCG Standards for Wildland Fire Chainsaw Operations, PMS 212, and Next Generation Position Task Book for Basic Faller Are Now Available

Date: April 14, 2025
Questions?  Please contact:
Hazard Tree and Tree Felling Subcommittee

The updated NWCG Standards for Wildland Fire Chainsaw Operations, PMS 212, and NWCG Position Task Book for Basic Faller (FAL3), PMS 311-19 are now available.

The NWCG Standards for Wildland Fire Chainsaw Operations, PMS 212 includes position standards designed to be used in conjunction with the Next Generation Position Task Book (Next Gen PTB). The Next Gen PTB for Basic Faller (FAL3) includes an evaluation guide with suggested rating elements to consider when assessing trainees.

References:

NWCG Standards For Wildland Fire Chainsaw Operations, PMS 212

NWCG Position Task Book for Basic Faller (FAL3), PMS 311-119

NWCG Basic Faller (FAL3)

RMC Memo 25-01: Summary of Updates to Safety Officer Positions

Date: April 9, 2025
Questions?  Please contact:
RMC Member Eric Fransted

The Risk Management Committee (RMC) serves as the position steward for all Safety Officer incident positions and continues to improve position standards, training, and naming conventions. The implementation of Complex Incident Management (CIM) required changes to position titles. RMC collaborated with the NWCG Incident Position Standards Committee (IPSC) to propose and implement these updates. 

References:

RMC Memo 25-01: Summary of Updates to Safety Officer Positions 

NWCG Position Catalog

Updated, NWCG Guide to Wildland Fire Origin and Cause Determination, PMS 412

Date: April 8, 2025
Questions?  Please contact:
Wildland Fire Investigation Subcommittee

PMS 412 provides guidance for wildland fire investigations. This guide outlines recommended procedures, practices, techniques, and methods to promote a systematic approach. The last update to this publication was in 2016.

References:

NWCG Guide to Wildland Fire Origin and Cause Determination PMS 412

Updated NWCG Standards for Airtanker Base Operations, PMS 508

Date: March 31, 2025
Questions?  Please contact:
Airtanker Base Operations Unit

The updated NWCG Standards for Airtanker Base Operations (SABO), PMS 508 standardizes operations and procedures at interagency airtanker bases to ensure safe, efficient, and effective operations in support of interagency goals and objectives.

References:

NWCG Standards for Airtanker Base Operations, PMS 508