Skip to main content

Dirty Nomex®

 

Nomex® is the brand name for a heat and flame-resistant textile made by the DuPont chemical company and first marketed in 1967. Today, more than three million firefighters and aviation personnel around the world are protected by structure fire turnout gear, wildland fire personal protective equipment (PPE), and flight suits and jackets made of Nomex®.

Nomex® is not flame-proof. It burns when you hold a flame to it, but stops burning once the heat source is removed. The thick woven structure of synthetic fibers is a very poor conductor of heat. When exposed to heat, the fibers expand, closing the spaces between them insulating the wearer. But to work correctly, Nomex® needs proper care.

Dirty Nomex®

  • Wash Nomex® like normal laundry, but always include a rinse cycle that adequately removes soaps and detergents.
  • Nomex® garments should never be subjected to strong oxidizing agents such as peroxides or bleaches. These products harm the physical strength of the fabric.
  • Tumble dry and remove while slightly damp. Over-drying damages the fabric.

Poison Oak/Ivy/Sumac on Nomex®

National Technology and Development Program (NTDP) conducted research on laundering Nomex® firefighting clothing that has been contaminated with urushiol oil (what causes the rash) from poison oak/ivy/sumac exposure.

  • NTDP recommends that fire clothing contaminated with urushiol oil be cleaned following normal Nomex® laundering procedures, with a degreaser such as a detergent or a laundry soap, and as soon as possible.
  • Extra care should be exercised when handling the contaminated clothing, and it should be kept separate from unaffected clothing and equipment.
  • Put the affected clothing in a marked bag if you are giving it to someone else to wash. Before handling the affected clothing, apply a skin-barrier product such as Ivy Block or Technu®.

Fuel-Soaked Nomex®

Flammable contaminants will reduce the thermal performance of any flame-resistant garment including Nomex®.

  • Proper and periodic cleaning is essential to maintain thermal protective performance.

 

Action Item -

Nomex® is not effective if it is excessively dirty, fuel-soaked, or has holes. Does your Nomex® need to be washed, repaired, or replaced?

 

Reference:

A 2008 SAFENET corrective action filed by the US Forest Service regarding poison oak reactions experienced by firefighters during the 2008 fire season in California.

 

Last Modified / Reviewed:


Have an idea or feedback?

Share it with the NWCG 6MFS Subcommittee
 


Follow NWCG on X and Facebook
 


 

NWCG Latest Announcements

NWCG Standards for Wildland Fire Chainsaw Operations, PMS 212, and Next Generation Position Task Book for Basic Faller Are Now Available

Date: April 14, 2025
Questions?  Please contact:
Hazard Tree and Tree Felling Subcommittee

The updated NWCG Standards for Wildland Fire Chainsaw Operations, PMS 212, and NWCG Position Task Book for Basic Faller (FAL3), PMS 311-19 are now available.

The NWCG Standards for Wildland Fire Chainsaw Operations, PMS 212 includes position standards designed to be used in conjunction with the Next Generation Position Task Book (Next Gen PTB). The Next Gen PTB for Basic Faller (FAL3) includes an evaluation guide with suggested rating elements to consider when assessing trainees.

References:

NWCG Standards For Wildland Fire Chainsaw Operations, PMS 212

NWCG Position Task Book for Basic Faller (FAL3), PMS 311-119

NWCG Basic Faller (FAL3)

RMC Memo 25-01: Summary of Updates to Safety Officer Positions

Date: April 9, 2025
Questions?  Please contact:
RMC Member Eric Fransted

The Risk Management Committee (RMC) serves as the position steward for all Safety Officer incident positions and continues to improve position standards, training, and naming conventions. The implementation of Complex Incident Management (CIM) required changes to position titles. RMC collaborated with the NWCG Incident Position Standards Committee (IPSC) to propose and implement these updates. 

References:

RMC Memo 25-01: Summary of Updates to Safety Officer Positions 

NWCG Position Catalog

Updated, NWCG Guide to Wildland Fire Origin and Cause Determination, PMS 412

Date: April 8, 2025
Questions?  Please contact:
Wildland Fire Investigation Subcommittee

PMS 412 provides guidance for wildland fire investigations. This guide outlines recommended procedures, practices, techniques, and methods to promote a systematic approach. The last update to this publication was in 2016.

References:

NWCG Guide to Wildland Fire Origin and Cause Determination PMS 412

Updated NWCG Standards for Airtanker Base Operations, PMS 508

Date: March 31, 2025
Questions?  Please contact:
Airtanker Base Operations Unit

The updated NWCG Standards for Airtanker Base Operations (SABO), PMS 508 standardizes operations and procedures at interagency airtanker bases to ensure safe, efficient, and effective operations in support of interagency goals and objectives.

References:

NWCG Standards for Airtanker Base Operations, PMS 508