5.1 Burn Area and Perimeter

The perimeter is the distance around the fire or along the handline. Perimeter is determined by adding the lengths of the various lines that enclose the black area of a fire. Because fires often burned in unusual shapes such as fingers, the perimeter of a fire can be approximated by assembling a combination of known shapes and lines. 

Area is the amount of surface covered within a given perimeter and is useful in determining burnout acreage. Area is always in square units: for example, square feet (ft2), square yards (yd2), or acres, which represents a square distance. 

A square, rectangle, and triangle are shown in the following figures, with their formulas for area and perimeter. 

square, circle, and triangle

Determining perimeter and burn area after a fire is often necessary. Average dimensions for a sketch can be obtained by pacing or walking around and through the burn. This method is especially useful for small fires. Global Positioning Systems (GPS) are used for larger fires to determine their shape, area, and perimeter. 

Example 1 - John sketched the following burn shape in his firefighter's notebook. Use this information to determine the acreage of the fire. John's pace is 12 paces per chain.

burned area shape

Step 1. Set up the cancellation table so all units will cancel, except the desired unit, chains.

cancellation table

Step 2. Take the average of the two widths. The average width = 8.5 chains + 3.5 chains / 2 = 12 / 2 = 6 chains.

Step 3. Use the equation for determining the area of a rectangle.
Area of rectangle = length × average width

Area = 10 chains × 6 chains = 60 square chains.

Step 4. Set up the cancellation table so all units will cancel, except the desired unit, acres.

cancellation table

The area of the fire is 6 acres.
 

ACREAGE GRID

A clear acetate/plastic dot acreage grid can be placed over the mapped sketch of a burn area. It is important that the plastic grid overlay and burn map have the same scale. Burn area is determined by counting the number of dots inside the sketch of the burn. For dots that are on the border of the burn sketch, count every other dot. Multiply the number of dots counted by the dot conversion factor. This conversion factor is typically indicated on the bottom of the plastic overlay. 

Example 2 - Janie sketched out a burn area in the following shape on a 7.5 minute USGS quadrangle map. The U.S. Geological Survey (USGS) produces a series of standard maps to various scales. The 7.5 minute map series has a 1:24,000 scale. One inch on a 7.5 minute map represents 2,000 feet on the ground. (See Chapter 6, Latitude and Longitude, for more information.) Use the acreage grid overlay to determine the area of the fire.

acreage grid

Step 1. Count the number of dots within the shape. Count every other dot for dots on the borderline. There are 181 dots.

Step 2. Read the overlay scale to obtain the dot-grid conversion. In this case the conversion is 2.500 acres per dot. 

Step 3. Set up the cancellation table so all units will cancel, except the desired unit, acres.

cancellation table

The area of the above figure is about 453 acres.

schematic of burn area with paces marked

 

NWCG Latest Announcements

NWCG Standards for Wildland Fire Chainsaw Operations, PMS 212, and Next Generation Position Task Book for Basic Faller Are Now Available

Date: April 14, 2025
Questions?  Please contact:
Hazard Tree and Tree Felling Subcommittee

The updated NWCG Standards for Wildland Fire Chainsaw Operations, PMS 212, and NWCG Position Task Book for Basic Faller (FAL3), PMS 311-19 are now available.

The NWCG Standards for Wildland Fire Chainsaw Operations, PMS 212 includes position standards designed to be used in conjunction with the Next Generation Position Task Book (Next Gen PTB). The Next Gen PTB for Basic Faller (FAL3) includes an evaluation guide with suggested rating elements to consider when assessing trainees.

References:

NWCG Standards For Wildland Fire Chainsaw Operations, PMS 212

NWCG Position Task Book for Basic Faller (FAL3), PMS 311-119

NWCG Basic Faller (FAL3)

RMC Memo 25-01: Summary of Updates to Safety Officer Positions

Date: April 9, 2025
Questions?  Please contact:
RMC Member Eric Fransted

The Risk Management Committee (RMC) serves as the position steward for all Safety Officer incident positions and continues to improve position standards, training, and naming conventions. The implementation of Complex Incident Management (CIM) required changes to position titles. RMC collaborated with the NWCG Incident Position Standards Committee (IPSC) to propose and implement these updates. 

References:

RMC Memo 25-01: Summary of Updates to Safety Officer Positions 

NWCG Position Catalog

Updated, NWCG Guide to Wildland Fire Origin and Cause Determination, PMS 412

Date: April 8, 2025
Questions?  Please contact:
Wildland Fire Investigation Subcommittee

PMS 412 provides guidance for wildland fire investigations. This guide outlines recommended procedures, practices, techniques, and methods to promote a systematic approach. The last update to this publication was in 2016.

References:

NWCG Guide to Wildland Fire Origin and Cause Determination PMS 412

Updated NWCG Standards for Airtanker Base Operations, PMS 508

Date: March 31, 2025
Questions?  Please contact:
Airtanker Base Operations Unit

The updated NWCG Standards for Airtanker Base Operations (SABO), PMS 508 standardizes operations and procedures at interagency airtanker bases to ensure safe, efficient, and effective operations in support of interagency goals and objectives.

References:

NWCG Standards for Airtanker Base Operations, PMS 508